- With the OEC 9900 Elite: Improve your workflow and productivity. OEC C -arms are consistently rated by customers as easy-to-use because of the intuitive user interface and software design. OEC University; Ultrasound Education. OEC 9900 Elite Main Brochure LR-990018-02. Please fill out the form below to access the requested information.
- The GE OEC 9900 first launched in 2006, and continuously introduced upgrade models such as the GE OEC 9900 Elite and OEC Elite with slight facelift and user interface upgrades. Although in 2017, GE cleared 510(k) for her new CMOS Flat Detector incorporated the GE OEC Elite CFD as a premium grade C-ARM system, the GE OEC 9900 with a 1k x 1k CCD camera and a traditional image intensifier type is.
- The OEC 9900 Elite is available in a number of configurations, allowing you to select the product features that best meet your clinical needs: Motorized C-arm 12” (31cm) I.I. Orthopedics, General Surgery and Pain Management.
Read Free Oec 9900 C Arm Service Manual interface and software design. The OEC 9900 Elite is the only “immediate image” fluoro system on the market. A dual control mainframe and left-to-right layout means easy access for fast operation. Optimize dose management. OEC 9900 Elite - OEC C-arms - Surgical Imaging - Categories. Service Technicians C-Arm Forum Service Manual Oec 9900 Jamal Bazzi Bazzimed Please I need the service manual for GE OEC 9900 C-arm. I need service manual GE 9900 Elite.
* Case Sensitive
Description
Generator
- 60kHz high frequency
- 15kW power
- Up to 120kVp
- Up to 75mA for radiographic film exposure
- Continuous high level fluoro (HLF) up to 20mA
- Digital spot up to 75mA
- Digital cine pulse
- 15 or 30 pulses per second, 60 Hz
- 12 or 25 pulses per second, 50 Hz
- Up to 150mA
- 10ms pulse width
- Full powerfrom standard wall outlet
- Patented battery buffered design
X-ray Tube
- Rotating anode X-ray tube
- 0.3 and 0.6 nominal focal spots
- Anode heat capacity: 300,000 HU
- Anode cooling rate: 85,000 HU/min.
- Housing heat capacity: 1,600,000 HU
- Housing cooling rate:
- 9” I.I. Super C- 22,500 HU/min
- 12” I.I. – 22,500 HU/min
Digital Image Rotation
- Digitally adjusts image display
- Automatic image update
- Image rotation
- Image reversal (side-to-side)
- Image invert (top-to-bottom)
- Image positioning without additional exposure
Preview Collimator
- On-screen collimator position indication
- PreView iris collimator
- PreView Tungsten rotatable double leaf collimator
- Adjusts collimators without X-ray exposure
Fluoro Mode
- kVp range: 40 -120
- mA range:
- 0.2 – 10 normal mode
- 1.0 – 20 HLF (high level fluoro)
- Auto and manual fluoro modes
- AutoTrak ABS varies mA, kVp, camera gain
Pulsed Fluoro Mode
- kVp range: 40 – 120
- mA range: 0.2 – 10
- Pulse rate: 1, 2, 4, 8
- Pulse width: 25 or 50ms
- AutoTrak ABS, mA, kVp, camera gain
- Reduces X-ray dose to patient and operator
High Level Pulsed Fluoro
- kVp range: 40 – 120
- mA range: 1 – 40
- Pulse rate: 1, 2, 4, 8
- Pulse width: 25 or 50ms
- AutoTrak ABS, mA, kVp, and camera gain
Digital Spot Mode
- kVp range: 40 – 120
- mA range: Up to 75
- Automatic exposure termination and automatic image save
Radiographic Mode
- mA range: up to 75
- mAs range: up to 300
- Computer controlled exposure time
- Optional film cassette holder
- 10” x 12” (24cm x 30cm) for 9” I.I.
- 14” x 14” (35cm x 35cm) for 12” I.I.
Video Imaging System
9″ Image Intensifier
Ge Oec 9900 Elite User Manual
- Tri-mode 9”/6”/4.5” (23cm/15cm/11cm) image intensifier
- Minimum central resolution (at monitor):
- 9” (23cm): 2.2 lp/mm
- 6” (15cm): 3.0 lp/mm
- 4.5” (11cm): 3.5 lp/mm
- DQE: 65% (typical)
12″ Image Intensifier
Ge Oec 9900 Training Manual
- Tri-mode 12”/9”/6” (31cm/23cm/15cm) image intensifier
- Minimum central resolution (at monitor):
- 12” (23cm): 1.6 lp/mm
- 9” (15cm): 2.2 lp/mm
- 6” (11cm): 2.6 lp/mm
- DQE: 65% (typical)
Precision Imaging with Dynamic Range Management (DRM)
- Preset Imaging Profile: Orthopedic
- Enhances features of interest while attenuating background noise
AutoTrak Automatic Brightness Stabilization (ABS)
- Automatically seeks the subject anatomy anywhere within the imaging field and selects the optimum imaging technique
- Automatically adjusts to anatomical size and location
- Provides uniform image quality throughout the entire image
- Simplifies operation
Oec C Arm User Manual
Image Quality Features
- Smart Window
- Dynamically senses the collimator position and automatically adjusts brightness and contrast to produce high image quality
- Smart Metal
- Allows user to adjust automatic brightness and contrast sensitivity levels to metal
- Provides optimum image quality even when metal is introduced to the field
- Tungsten Collimator
- Dense collimator limits X-ray exposure area
- Reduces scatter radiation
- mproves image detail
Video Camera
- High resolution 1k x 1k CCD camera
- Full frame capture
- Motorized rotation
- On-screen orientation indicator (real-time feedback without fluoro)
- Left-right image reversal
- Top-bottom image invert
Oec 9900 Elite User Manual Pdf
Video Display
Oec 9900 Elite User Manual
- Dual 19” (48cm) display anti-glare, LCD flat panel monitors mounted on an articulating arm
- 22” horizontal travel
- 7° up/10° down
- Monitors viewable from all four sides of workstation
- Horizontal and vertical viewing angle 170°
- 1200 CD/M2 maximum brightness
- Touch screen system control
- 1280 x 1024 high resolution monitors
- Integrated color monitor for display of VGA, DVI, DVI-D, S-VHS, and SDISD formats